cytosense flow cytometer
|
cytosense scanning flow cytometer - basic version
-
20 mW blue-green (488 nm) high quality laser module (other wavelengths or power
available, flat light distribution for high flow rates
- volumetric, valveless, auto-ranging sample dosing system
- ultrawide (1x1mm ) flow cuvette with 2-stage hydrodynamic sheath fluid injection
system, speed controlled, external & recirculating mode
- 3 detectors: one (1) forward scatter (photodiode) and two (2) photomultiplier tubes
(PMT) for side scatter and/or fluorescence (selectable);
- scanning data format: full pulse profile digitizing electronics for morphological
particle analysis(nano- and microplankton)
- laptop computer with 'CytoUSB' software for instrument operation in various modes
(automated, interactive and scheduled-mode)
- 'CytoClus' data analysis software: flow cytometry cluster analysis software
extended with individual particle profile visualization and parameterization: up to 8
parameters from each detector output
extra measuring detectors
The standard CytoSense PMT detectorunit can be upgraded with maximally 2 extra PMT's
and the forward scatter unit can be upgraded with one extra detector for curvature
analysis. Therewith the main system can contain up to a total of 6 detectors.
|

|
examples of extra pmt's
| Deep red fluorescence: | the main chlorophyll emission band | |
Orange fluorescence: | allows distinction of species containing accessory pigments
such as erythrins and phycobilins | |
Yellow/Green fluor.: | typical for certain ciliates and cysts and sometimes lysing
cells (such as after being ingested by zoo-plankton) - also
useful for arteficial fluorescent staining of cellular
components, DNA etc. | |
Side scatter: | allows classification of particles with relatively high
internal/external structure, for instance Coccolithophores
and gas vacuolate species. | |
Curvature detector: | Upgrades the existing FWS photodiode to a pair of
photodiodes with polarization analysis for the combined
detection of forward scatter, lateral position and curvature.
For the detection of spiral shapes, tabellaria type and curved
cells and colonies. |
| |
picoplankton options
for the detection of very small particles such as picoplankton
species and bacteria we offer three options for upgrading your CytoSense.
Picoplankton option A - Instrument settings (including PMT yield, sheath and
sample flow rates, higher laser power etc.) optimized for small particles. Note that this
renders scanning data less useful for big species.
Picoplankton option B - Control circuitry and software that allows 'mouse click' switching
(also in preprogrammed mode) between two types of instrument settings such as 'high'
sensitivity (as in option A) and 'low' sensitivity.
Picoplankton option C - Includes the mounting of an extra detection unit with
1 to 4 extra detectors operated at high sensitivity for the detection of picoplankton.
2-laser option
The CytoSense optical unit can be upgraded with a second laser to increase the available
excitation/emission combinations for optimum species recognition and/or multiple color
flow cytometry. In the case of 2-laser operation the following laser lines can be chosen
from:
For laser 1: 460 nm or 488 nm or 532 or 561 nm.
Laser 2: 445 nm or 635 or 640 or 660 nm.
|
|